Size: 1/2 inch to 6 inches
Flanges: Standard - Stainless Steel / Aluminum, Optional - Titanium, Hastelloy, Monel
Power supply: 2/3 wire; 13.5 - 30VDC und, 4 wire, 115 VAC, 230 VAC
Output signal: 0-20mA; 4-20mA, Pulse
Accuracy: 1.6 % accuracy (qG = 50 %)
Type: Volume Type Flow Meter
Measuring Principle: Mechanics
Flow Range: DN15-DN250
Temperature: -20-200 Degree
Material: Case Stee/Cast Iron/Stainless
Pressure: 1.6MPa
Medium: Oil,Fuel,Gas
Measurement Object: Closed Pipeline
Flow Range: Flow Range
Medium: Gas, Liquids
Process temperature: -20°C to 80°C, 0°C to 150°C, 0°C to 250°C
Accuracy & Repeatability: 0.1% & <0.033%, 0.2% & <0.067%, 0.5% & <0.167%
Nominal Pressure: 16 bar, 25 bar, 40 bar, 64 bar
Viscosity Ranges: 0~20000 mPa.s
Flange Connection: Customer Standards
Nominal passage: 10m≤DN≤3000 mm
Accuracy grade: ±0.5%, ±1.0%
Repeatability: ≤0.1%
Turndown ratio: 1: 10 or 1:15
Requirements for installing straight pipe sections: front 0.5D and rear 0.5D
Medium operating pressure: ≤25MPa
Permanent pressure loss (Pa): ≤0.31pV2 (ρ bulk density kg/m3 V average flow rate m/s)
Principle: Transit-time ultrasonic flowmeter
Accuracy: ±1%
Signal output: 1-way 4-20 mA output, electric resistance 0-1 K, accuracy 0.1%, 1-way OCT pulse output (Pulse width-1000 ms, default is 200 ms), 1-way Relay output
Signal input: 3-way 4-20 mA input, accuracy 0.1%, acquisition signal such as temperature, pressure and liquid level. Connect the temperature transducer PT-100, can finish the heat/energy measurement.
Data Interface: Insulate RS-485 serial interface, upgrade the flowmeter software by computer, support the MODBUS.
Pipe material: Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel, product, liner is allowed.
Pipe diameter: 15- 6000 mm
Straight pipe: Transducer installation should be satisfied: upstream 10 D, downstream 5 D, 30 D from the pump.
Type of liquid: Single liquid can transmit sound wave; such as water (hot water, chilled water, city water, sea water, waste water, etc.); sewage with small particle con tent, oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); chemicals (alcohol, etc.); plant effluent; beverage; Ultra-pure liquids, etc.
Temperature: Convertor; -20- 60℃; Flow Transducer: -30-160℃
Turbidity: No more than 10,000 ppm and less bubble
Flow rate: 0-±7 m/s
Humidity: Convertor: 85% RH; Flow Transducer: can measure under water, water depth ≤2 m
Power Supply: DC 8-36 V or AC 85-264 V (Optional)
Power Consumption: 1.5 W
Size: 4 mm to 200 mm
Accuracy Class: Standard 0.5 % of Rate
Measurement Ratio: Standard 10 :1 , Optional 20 :1
Construction: Compact & Separate Version
Medium: Liquid, Water , Diesel , Dry Gases etc.
Connections: Thread, Flange & Wafer Available
Process Temp: -20°C to 150°C
Communication: RS 485, HART, MODBUS
Protection Class: IP 65, IP 67 (Optional)
Signal Output: 4 to 20 mA, Pulse, Alarm Optional
Sensor Housing: SS304 , Other materials( SS 316) on request
Convertor Housing: Standard Polyurethane Coated Die Cast Aluminum
Measured Medium: Liquid, Gas, Steam
Medium Temp: -40°C to 250°C;
High Temp: -40°C to 350°C
Flange: DIN PN10/PN16/PN25/PN40, JIS10K/20K/30K/40K, ANSI 150#/300#
Pressure: Flange - 40 BAR, Thread - 16 BAR, Tri-clamp - 16 BAR, Insertion - 16 BAR
Accuracy: ±1.0% (Flange/Wafer/Thread/Tri-clamp), ±1.5% (Insertion type), Liquid:0.4-7.0m/s, Gas:4.0-60.0m/s, Steam:5.0-70.0m/s
Specifications: DN15-DN300 (flange/wafer type), DN80-DN2000 (insertion type), DN15-DN100 (thread/sanitary type)
Body Material: SS304 (standard), SS316 (optional)
Power Supply: DC12-30V or 3.6V lithium battery powered
Signal Output: 4-20mA, Pulse
Communication: RS485 Modbus or HART